Error 1 No Water

Model Touch 2

Reasons for occurrence:

To reset the error, press the CONTROLLER REBOOT button. If the error does not reset, start the pumping water process in the service menu. When is complete, press the CONTROLLER REBOOT button.

If the error reappears after a reboot, perform diagnostics:

A separate setting is used for each type of connection.


Pumps ajusting

If, after completing the connection, water is supplied but error 1 No Water continues to appear upon reboots, it is necessary to check the water level in the mixer. Start pumping in the service menu and compare the flow level with the picture:

If the water level is below the green line, increase the water flow. To do this, open the service menu and go to the Configurator - Service Menu section. Find the «PWM water settings» option.

By default, the value is set to 40%. Moving the slider to the left will make the pressure weaker, moving it to the right will increase it. To save the change, you must press the «Write» button. It is not recommended to sharply increase/decrease the pressure; change the values by 10% at a time, making sure to save the value, reboot the machine, and check for the appearance of error 1.

After changing the PWM setting, water calibration is mandatory for correct calculation of drink dosages.


Central water system ajusting

If, after completing the connection, water is supplied but error 1 No Water continues to appear upon reboots, it is necessary to check the water level in the mixer. Start pumping water in the service menu and compare the flow level with the picture:

If necessary, adjust the water flow.