To use this type of connection, preparation of the water supply system is required. Using a direct connection to the water main is not recommended; typically, 3 or 5-cell filters are used for water purification.
Depending on the date of manufacture, the machine can be equipped with two configurations of water supply - with ULKA, or 24V pumps. The steps for preparing the water supply are the same for both configurations.
Attention! Installation of water flow control devices is prohibited!
A 6mm diameter PVC hose is used to connect to the machine's fitting. Ensure the pressure in the water supply system is not below 0.15 - 0.8 MPa (1.5 - 8 bar).
Connection procedure and rules:
If, after completing the connection, water is supplied but error 1 No Water continues to appear upon reboots, it is necessary to check the water level in the mixer. Push Pumping water in the service menu and compare the flow level with the picture:
The water supply connection setup is complete.
In some cases, with increased pressure in the water supply system, the solenoid valve may not open (the machine shows Error 1, and water does not pump upon reboot). The solution is to reduce the pressure using the regulator by turning it counter-clockwise several turns, then press CONTROLLER REBOOT and ensure that water begins to flow into the line. After any changes to the water pressure, it is necessary to perform water calibration in the Configurator - Conversion factor tab.